Seawall raising in Jupiter
Seawall raising in Jupiter, where a seawall cap may not rise above base flood elevation.
Free Fast Quote
Please fill out this form to request a free quote on your upcoming project and we will respond to you right away!
Cities across South Florida now set minimum seawall heights. We work out which standard applies to your lot and whether a new cap or a new wall gets you there.
- Free, no-obligation quote
- Fast response from our team
- Miami-Dade, Broward, Palm Beach and the Keys
The short answer
In Jupiter the top of a seawall cap must be at or below the property's base flood elevation, read from FEMA maps effective 20 December 2024. Jupiter's current FEMA flood maps took effect on 20 December 2024, and the Town says its scattered flood areas put every property at some risk.
Last updated
Who needs a seawall raised
Owners whose walls overtop at king tides, owners who have been cited, and owners planning a repair big enough to trigger the city's height rule.
- Water over the cap at high tide
- A city citation for overtopping
- A repair of $300 or more per linear foot in Miami Beach
- Plans to sell, rebuild or add a dock
Typical project sizes
Raising is either a new cap on a sound wall or a full new wall. Miami Beach's 2017 rule of thumb was $1,000 to $1,500 per linear foot to bring an old seawall up to code.
A cap no higher than base flood elevation
Jupiter caps seawalls from above: the top of the concrete cap, in NAVD, must be at or below the property's base flood elevation (Code 27-2624(8)). Since FEMA's new maps took effect on 20 December 2024, the BFE on the current map is the number to check before a cap is designed.
A raise is designed to that number, measured in the right datum, and checked by survey before the cap pour.[1][2]
New flood maps since December 2024
FEMA's new flood maps for Jupiter took effect on 20 December 2024, and the Town warns that its flood hazard areas are scattered, so every property can flood. Owners whose zone changed may need to adjust their insurance, and that zone decides whether vents or barriers are required or simply sensible.
Raising the wall stops tidal overtopping, but the home behind it still relies on its own flood protection.[2]
Inlet tide on the Loxahatchee
NOAA's Jupiter Inlet south jetty station records a 2.39 ft mean range and a 2.75 ft great diurnal range, with mean higher high water about 0.19 ft above NAVD 88 (1983 to 2001 epoch). Lift travel and floating dock gangways near the inlet are planned from this gauge.

Those numbers show how much margin a raised wall really gives above an ordinary high tide.[3]
Free advice from Town staff
Town staff will visit a property to review flood concerns and can advise on flood panels, berms, flood walls and raising structures. In a Special Flood Hazard Zone, work costing 50% or more of the building's market value is a substantial improvement and must bring the whole building to current code.[4]
What makes Jupiter different
Town Code 27-2626 keeps half of every waterway clear: a centreline channel of 50% of the waterway width must stay unobstructed, or at least a 15 ft channel where that cannot be met. Only rectangular, T and L shaped docks are allowed unless the Planning and Zoning Director approves another shape.[6]

Who approves what
The Town's checklists ask for FDEP self-certification or exemption verification, Army Corps approval if not included in the DEP decision, and SFWMD approval for structures on submerged lands or in natural waterways such as the Loxahatchee River, the Intracoastal Waterway and Sawfish Bay.[1][5]

Permits in Jupiter
- Town of Jupiter Building and Planning and Zoning: Marine structure permits; dock waivers under Town Code 27-2626.
- Florida DEP or South Florida Water Management District: FDEP self-certification or exemption verification for canal docks; SFWMD approval for structures in the Loxahatchee River, the Intracoastal and Sawfish Bay.
- US Army Corps of Engineers, Jacksonville District: Army Corps approval where the FDEP decision does not include it, as the Town checklists note.
Seawall height rules by city
Each city sets its own standard, and they do not all use the same vertical datum (NAVD 88 or the older NGVD 1929), so the engineer's survey must state the wall height in the same datum as your city's rule.

Miami Beach: 5.7 ft NAVD for new walls and substantial repairs, or 4 ft NAVD designed to reach 5.7 ft. Coral Gables: a minimum of 6 ft NGVD 1929, structurally able to support 7.5 ft. Fort Lauderdale: a minimum of 5 ft NAVD88, and walls permitted before 1 January 2035 may be built at 4 ft if designed to reach 5 ft by 1 January 2050. Boca Raton: new or replaced walls between 4.0 and 6.0 ft NAVD88, designed to take another 12 to 18 inches.
City of Miami: a 2020 proposal set 6 ft NAVD 88 east of US-1. We have not confirmed it was adopted, so we check with the City for each job.[7][11][13][14][10]
Help with the cost
Miami Beach's Private Property Adaptation program accepts seawall applications on a rolling basis and reimburses 50% of costs up to $20,000, including the $2,500 assessment value; qualifying low to moderate income households need no match up to $17,500. Homes built at least 1 ft above base flood elevation are not eligible. Coral Gables waives a fee for existing homes raising seawalls for sea level rise.[8][12]

| City | Standard or incentive | Source |
|---|---|---|
| Miami Beach | 5.7 ft NAVD (or 4 ft designed for 5.7 ft) | City FAQ, June 2025 |
| Miami Beach | Grant: 50% of costs up to $20,000 | PPA program page |
| Coral Gables | Minimum 6 ft NGVD 1929, supports 7.5 ft | City Attorney opinion, 2022 |
| Coral Gables | Fee waiver for raising existing residential seawalls | City permits page |
| Fort Lauderdale | Minimum 5 ft NAVD88 | City staff report, 2022 |
| Boca Raton | 4.0 to 6.0 ft NAVD88 | Engineering Design Standards, 2025 |
Frequently asked questions
Is there a maximum seawall height in Jupiter?
Yes. The top of the cap in NAVD must be less than or equal to the property's base flood elevation (Code 27-2624(8)).
Did Jupiter's flood zones change recently?
Yes. FEMA's new flood zone maps took effect on 20 December 2024. Check your zone, because insurance and building requirements follow it.
How much does the tide move in Jupiter?
At NOAA's Jupiter Inlet south jetty station, a 2.39 ft mean range and a 2.75 ft great diurnal range (1983 to 2001 epoch).
Can the Town of Jupiter advise me on flood protection?
Yes. Staff will visit a site and advise on flood panels, berms, flood walls and elevating structures.
Sources
- Marine Structure: Seawalls permit checklist (revised January 2021), Town of Jupiter Building Department. Accessed October 28, 2026.
- Flood Zones and Insurance Information, Town of Jupiter. Accessed October 28, 2026.
- Datums for station 8722495, Jupiter Inlet, south jetty (tidal epoch 1983 to 2001), NOAA Center for Operational Oceanographic Products and Services (CO-OPS), Tides and Currents. Accessed October 28, 2026.
- Flood Mitigation Advice, Town of Jupiter. Accessed October 28, 2026.
- Marine Structure: Docks permit checklist (revised January 2021), Town of Jupiter Building Department. Accessed October 28, 2026.
- Application for Dock Waiver (form dated 14 Mar 2016, quoting Town Code 27-2626), Town of Jupiter Department of Planning and Zoning. Accessed October 28, 2026.
- Seawall FAQs (Miami Beach Rising Above, PDF dated 6.16.25), City of Miami Beach. Accessed October 27, 2026.
- Private Property Adaptation (PPA) program, City of Miami Beach (Miami Beach Rising Above). Accessed October 27, 2026.
- Rising Above the Risk: Frequently Asked Questions (05/05/2017), City of Miami Beach. Accessed October 27, 2026.
- City of Miami File ID 7338 (Revision A): Ordinance amending Chapters 20, 29 and 54 to set seawall minimum heights (Second Reading, printed 5/19/2020), City of Miami. Accessed October 27, 2026.
- CAO 2022-007: Legal Opinion Regarding Scrivener's Error in Zoning Code 3-706 Bulkheads and Retaining Walls (17 Aug 2022), City of Coral Gables, City Attorney. Accessed October 27, 2026.
- Solar, Open Air Dining, and Other Permits, City of Coral Gables. Accessed October 27, 2026.
- Staff Report, Planning and Zoning Board, 16 Nov 2022, Case UDP-T22010 (Tidal barrier / seawall ordinance amendment, ULDR 47-19.3), City of Fort Lauderdale. Accessed October 27, 2026.
- Engineering Design Standards Manual, section 7.7 Minimum Criteria for Waterway Features (PDF modified 10 Apr 2025), City of Boca Raton. Accessed October 28, 2026.
Get a free quote
Tell us about your project and we will get back to you fast.